| NC316BU-1/AC |
|
Single-slot Chassis with Internal 90-240V AC Power Supply. Desk Top |
| NC316BU-1/DC |
|
Single-slot Chassis with Internal -48V DC Power Supply. Desk Top |
| NC316BU-1/NP |
|
Single-slot chassis with no power supply. To be used only with passive modules. |
| NC316BU-1AC/EU |
|
Single-slot chassis with internal 200-250 VAC Power Supply (European version), no power cable is provided |
| NC316BU-1HP/AC |
|
Single-slot High Power Chassis with Internal 90-240V AC Power Supply. To be used with all Single Fiber modules |
| NC316BU-1HP/DC |
|
Single-slot High Power Chassis with Internal -48V DC Power Supply. To be used with all Single Fiber modules |
| NC316BU-2/AC |
|
2-slot chassis with Internal 90-240V AC Power supply (One single slot blank panel included). |
| NC316BU-2/DC |
|
2-slot chassis with Internal -48V DC Power supply (One single slot balnk panel included). |
| NC316BU-3/AC |
|
3-slot chassis with Internal 90-240V AC power supply (second PS is optional; Two single slot blank panels included). |
| NC316BU-3/DC |
|
3-slot chassis, one DC power supply (second PS is optional; Two single slot blank panels included). |
| NC316BU-4/AC |
|
4-slot Chassis with Internal 90-240V AC Power Supply (Two single slot blank panels & 19" mounting brackets included). |
| NC316BU-4/DC |
|
4-slot Chassis with Internal -48V DC Power Supply (Two single slot blank panels & 19" mounting brackets included). |
| NC316BU-16/AC |
|
16-slot Chassis with Internal 90-240V AC Power Supply (Three single slot and two four slot blank panels included). |
| NC316BU-16/DC |
|
16-slot Chassis with Internal -48V DC Power Supply (Three single slot and two four slot blank panels included). |
| NC316BU-16/DC3 |
|
Triple Redundancy 16-slot Chassis, Three Segment Backplane for 19" rack -DC Power (Three single slot and two four slot blank panels included). |
| NC316BU-16T/DC |
|
16-slot, 23" rack mountable chassis with -48V DC power supply with front access (Three single slot and two four slot blank panels included). |
| NC316-2SFP16 |
|
16 Channel 2R SFP to SFP Repeater Chassis. |
| NC316-2SFP16NM |
|
16 Channel 2R SFP to SFP Repeater Chassis with Management Card. |
| NC316-3RPSAC |
|
Redundant Power Supply for NC316BU-3/AC (90-240V AC) |
| NC316-3RPSDC |
|
Redundant power supply for NC316BU-3/DC |
| NC316-4RPSAC |
|
Redundant Power Supply for NC316BU-4/AC (90-240V AC) |
| NC316-4RPSDC |
|
Redundant Power Supply for NC316BU-4/DC (-48VDC). |
| NC316-16RPSAC |
|
Redundant Power Supply for NC316BU-16 (90-240 VAC) |
| NC316-16RPSDC |
|
Redundant Power Supply for NC316BU-16 (-48 VDC) |
| NC316-16TRPSDC |
|
Redundant Power supply for the NC316BU-16T/DC (-48V DC) |
| NC316BU-16CMT |
|
Cable Management Tray for NC316BU-16 |
| NC316-16BRACKET |
|
Rack Mount Bracket for 16-slot chassis |
| NC316RB23-3 |
|
Rack Mount Bracket for NC316BU-3/AC or 3/DC Telco Chassis; 23" |
| NC316RB23-4 |
|
Rack Mount Bracket for NC316BU-4/AC or 4/DC Telco Chassis; 23" |
| NC316RB23-16 |
|
Rack Mount Bracket for NC316BU-16/AC Chassis, 23" |
| NC316MB-1 |
|
Wall Mount Bracket for NC316BU-1 |
| NC316MB-2 |
|
Wall Mount Bracket for NC316BU-2 |
| NC316BP-1 |
|
Blank Panel, single slot wide, for NC316 |
| NC316BP-4 |
|
Blank Panel, four-slot wide, for NC316BU-16 |
| NC316DCC |
|
DC Power Female Connector (WAGO) |
| EM316NM |
|
SNMP Management Module with 1 10Base-T Port and an RS232 Interface |
| EM316LX1 |
|
Linux-based secure console Server unit with (1) RS232 RJ45 port, and internal V.90 modem. Includeds software and documentation on CD-ROM and 3-year warranty. |
| EM316LX2 |
|
Linux-based secure console standalone unit with (2) RS232 RJ45 ports. Includes software and documenation on CD-ROM, and 3-year warranty. |
| EM316SC/3M |
|
Combiner/Splitter combines TX and RX outputs onto a single fiber strand. (MM; 1310nm; 62.5 micron; SC/SC-APC) |
| EM316SC/3S |
|
Combiner/Splitter, TX and RX outputs on single fiber strand. (SM; 1310nm; 9 micron; SC/SC-APC) |
| EM316SC/5S |
|
Combiner/Splitter, TX and RX outputs on single fiber strand. (SM; 1550nm; 9 micron; SC/SC-APC). |
| EM316SC/8M |
|
Combiner/Splitter, TX and RX outputs onto single fiber strand. (SM;850nm; 62.5 micron; SC/SC-APC). |
| EM316SC/MS |
|
Combiner/Splitter, TX and RX outputs on tosingle fiber strand (SM; 1270-1610nm; 9 micron; DSC/DSC-APC). |
| EM316MR-3R |
|
Multi-Rate SFP Converter up to OC-48 speeds with Quad CDR. |
| EM316DMR-3R |
|
Multi-Rate SFP Converter up to OC-48 speeds with Dual CDR. |
| EM316GBIC-SFP |
|
Protocol Independent GBIC to SFP Media Module. |
| EM316-2GBIC |
|
Two-Slot GBIC to GBIC Transparent Media Module. |
| EM316-2SFP |
|
Protocol Transparent Fiber Media Module. |
| EM316GEMX2R |
|
SFP-based TDM Multiplexer capable of multiplexing two (2) Gigabit-speed data channels onto one trunk with redundant link. |
| EM316MRMX2R |
|
SFP -based TDM Multiplexer capable of multplexing two (2) Gigabit Ethernet or Fibre Channel-speed data channels onto one trunk with redundant link |
| EM316EFRMAHSH |
|
10/100Base-TX (RJ45) Ethernet Copper to Redundant SFP based Fiber trunk with IP-Less Remote Management; 802.3AH compliant. |
| EM316GRMAHSH |
|
User port Auto-sensing between 10/100/1000Mbps Copper and SFP Based Fiber , to Redundant Fiber SFP Based Trunk, 802.3AH, with IP-Less Remote Management. |
| EM316EFE1RM |
|
E1 (BNC) & Ethernet/Fast Ethernet (RJ45) to SFP Based Trunk with Remote Management. |
| EM316E/M |
|
10Base-TX(RJ45) to 10Base-FL MM (850nm;ST) 0-2km |
| EM316E/MX |
|
10Base-TX to 10Base-FL (MM, 1310nm, 5-10km), ST. |
| EM316E/S1 |
|
10Base-TX (RJ45) to 10Base-FL SM (1310nm;ST) 1-25km |
| EM316E/S2 |
|
10Base-TX (RJ45) to 10Base-FL SM (1310nm;ST) 25-50km |
| EM316E/S3 |
|
10Base-TX (RJ45) to 10Base-FL SM (1550nm:ST) 50-100km |
| EM316E/S4 |
|
10Base-TX to 10Base-FL (SM, 1550nm, 50-125km) ST. |
| EM316E/S5 |
|
10Base-TX to 10Base-FL (SM, 1550nm, 50-135km) ST. |
| EM316ESF/S2 |
|
10Base-TX to 10Base-FL, Single Fiber (SM;1310nm;25-50km) ST. |
| EM316ESF/S3 |
|
10Base-TX to 10Base-FL, Single Fiber (SM; 1550nm; 50-100km) ST. |
| EM316ESF/S4 |
|
10Base-TX to 10Base-FL (SM, 1550nm, 40-105km) SC-APC. |
| EM316WEC/S2 |
|
2 Wavelength Single Fiber Ethernet copper to fiber converter, 10BaseT (RJ45) to Single Fiber Strand (SM, TX-1550nm, RX-1310nm, 10-45km, SC). Purchase in pairs. |
| EM316WET/S2 |
|
2 Wavelength Single Fiber Ethernet copper to fiber converter, 10BaseT (RJ45) to Single Fiber Strand (SM, TX-1310nm, RX-1550nm, 10-45km, SC). Purchase in Pairs. |
| EM316WEC/S3 |
|
2 Wavelength Single Fiber Ethernet copper to fiber converter, 10BaseT (RJ45) to Single Fiber Strand (SM, TX-1550nm, RX-1310nm, 30-50km, SC). Purchase in Pairs. |
| EM316WET/S3 |
|
2 Wavelength Single Fiber Ethernet copper to fiber converter, 10BaseT (RJ45) to Single Fiber Strand (SM, TX-1310nm, RX-1550nm, 30-50km, SC). Purchase in Pairs. |
| EM316ERM/M |
|
10Base-TX to 10Base-FX (MM, 850nm, 0-2km), DSC. |
| EM316ERM/MX |
|
10Base-TX to 10Base-FX (MM, 1310nm, 2-8km), DSC. |
| EM316ERM/S1 |
|
10Base-TX to 10Base-FX (SM, 1310nm, 0-35km), DSC. |
| EM316ERM/S2 |
|
10Base-TX to 10Base-FX (SM, 1310nm, 25-45km), DSC. |
| EM316ERM/S3 |
|
10Base-TX to 10Base-FX (SM, 1550nm, 35-90km), DSC. |
| EM316ERM/S4 |
|
10Base-TX to 10Base-FX (SM, 1550nm, 40-110km), DSC. |
| EM316ERM/S5 |
|
10Base-TX to 10Base-FX (SM, 1550nm, 45-130km), DSC. |
| EM316ERMSF/S2 |
|
10Base-TX to 10Base-FX, Single Fiber (SM, 1550nm, 0-35km), SC-APC. |
| EM316ERMSF/S3 |
|
10Base-TX to 10Base-FX, Single Fiber (SM, 1550nm, 25-70km), SC-APC. |
| EM316ERMSF/S4 |
|
10Base-TX to 10Base-FX, Single Fiber (SM, 1550nm, 35-100km), SC-APC. |
| EM316WERMC/S2 |
|
2 wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, SC), with IP-Less Remote Management, 0-30km. |
| EM316WERMT/S2 |
|
2 wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, TX:1310nm, RX:1550nm, SC), with IP-Less Remote Management, 0-30km. |
| EM316WERMC/S3 |
|
2 wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, SC), with IP-Less Remote Management, 20-45km. |
| EM316WERMT/S3 |
|
2 wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, 1550, SC), with IP-Less Remote Management, 20-45km. |
| EM316WERMC/EZX |
|
2 Wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM; TX:1550nm, RX: 1590nm; SC), 30-120km. |
| EM316WERMT/EZX |
|
2 Wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM; TX:1590nm, RX: 1550nm; SC), 30-120km. |
| EM316EFAN/M |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (MM, 1310nm, 0-2km, DSC). |
| EM316EFAN/MX |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (Extended MM, 1310nm, 2-8km, DSC). |
| EM316EFAN/S |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (SM, 1310nm, 0-20km, DSC). |
| EM316EFAN/S1 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (SM, 1310nm, 0-35km, DSC). |
| EM316EFAN/S2 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (SM, 1310nm, 25-45km, DSC). |
| EM316EFAN/S3 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (SM, 1550nm, 35-90km, DSC). |
| EM316EFAN/S4 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (SM, 1550nm, 40-110km, DSC). |
| EM316EFAN/S5 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, (SM, 1550nm, 45-130km, DSC). |
| EM316EFANSF/S2 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, Single Fiber (1310nm, 0-35km, SC-AP). |
| EM316EFANSF/S3 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, Single Fiber (1550nm, 35-70km, SC-AP). |
| EM316EFANSF/S4 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, Single Fiber (1550nm, 35-100km, SC-AP). |
| EM316EFANSF/S5 |
|
One port 10/100TX (RJ45)Auto Negotiation and One port 100Base-FX, Single Fiber (1550nm, 50-110km, SC-AP). |
| EM316WEFANC/S2 |
|
2 wavelength WDM, 10/100 Copper (RJ45) Auto Negotiation to Single Strand Fiber (SM, TX-1550nm, RX-1310nm, 0-25km, SC). |
| EM316WEFANT/S2 |
|
2 wavelength WDM, 10/100Base Copper (RJ45) Auto Negotiation to Single Strand Fiber (SM, TX-1310nm, RX-1550nm, 0-25km, SC). |
| EM316WEFANC/S3 |
|
2 wavelength WDM, 10/100 Copper (RJ45) Auto Negotiation to Single Strand Fiber (SM, TX-1550nm, RX-1550nm, 20-45km, SC). |
| EM316WEFANT/S3 |
|
2 wavelength WDM, 10/100 Copper (RJ45) Auto Negotiation to Single Strand Fiber (SM, TX-1310nm, RX-1550nm, 20-45km, SC). |
| EM316WEFANC/EZX |
|
2 Wavelength WDM, 10/100 Copper (RJ45) Auto Negotiation to Single Strand Fiber (SM; TX:1550nm, RX:1590nm; SC), 30-120km. |
| EM316WEFANT/EZX |
|
2 Wavelength WDM, 10/100 Copper (RJ45) Auto Negotiation to Single Strand Fiber (SM; TX:1590nm, RX:1550nm; SC), 30-120km. |
| EM316EFRM/M |
|
Auto-negotiate 10/100Base-TX Ethernet Copper to Multimode Dual Fiber with IP-Less Remote Management; 0-2km. |
| EM316EFRM/S |
|
Auto-negotiate 10/100Base-TX (RJ45)Ethernet Copper to MM Dual Fiber (DSC, 1310nm) with IP-Less Remote Management; 0-20km. |
| EM316EFRM/S1 |
|
Auto-negotiate 10/100Base-TX Ethernet Copper to Multimode Dual Fiber with IP-Less Remote Management; 0-35km. |
| EM316EFRM/S2 |
|
Auto-negotiate 10/100Base-TX Ethernet Copper to Multimode Dual Fiber with IP-Less Remote Management; 24-45km. |
| EM316EFRM/S3 |
|
Auto-negotiate 10/100Base-TX Ethernet Copper to Multimode Dual Fiber with IP-Less Remote Management; 35-90km. |
| EM316EFRM/S4 |
|
Auto-negotiate 10/100Base-TX Ethernet Copper to Multimode Dual Fiber with IP-Less Remote Management; 40-110km. |
| EM316EFRM/S5 |
|
Auto-negotiate 10/100Base-TX (RJ45)Ethernet Copper to SM Dual Fiber (DSC, 1550nm) with IP-Less Remote Management; 45-130km. |
| EM316EFRMSF/S |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Single Fiber (SC-APC; 1310nm) with IP-Less Remote Management; 0-20km. |
| EM316EFRMSF/S2 |
|
Auto-negotiate 10/100Base-TX Ethernet Copper to Singlemode, Single Fiber (SC-APC, 1310nm) with IP-Less Remote Management; 0-35km. |
| EM316EFRMSF/S3 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to Singlemode, Single Fiber (SC-APC, 1550nm) with IP-Less Remote Management; 25-70km. |
| EM316EFRMSF/S4 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to Singlemode, Single Fiber (SC-APC, 1550nm) with IP-Less Remote Management; 35-100km. |
| EM316EFRMSF/S5 |
|
Auto-negotiate 10/100Base-TX (RJ45)Ethernet Copper to SM, Single Fiber (SC-APC, 1550nm) with IP-Less Remote Management; 50-110km. |
| EM316WEFRMC/S2 |
|
2 Wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 0-25km, WDM) with IP-Less Remote Management;. |
| EM316WEFRMT/S2 |
|
2 Port Module, 1 port 10/100Base TX (RJ45) Autosensing to 100Base FX Single Fiber (SM, TX-1310nm, RX-1550nm, 0-25km, WDM), with IP-Less Remote Management. |
| EM316WEFRMC/S3 |
|
2 Wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 20-45km, WDM) with IP-Less Remote Management. |
| EM316WEFRMT/S3 |
|
2 Wavelength WDM, 10Base-TX (RJ45) to Single Strand Fiber (SM, TX-1310mn, RM-1550nm, 20-45km, WDM) with IP-Less Remote Management. |
| EM316WEFRMC/EZX |
|
2 Port Module, 1 port 10/100Base RJ45 Autosensing to 100BaseFX Single Fiber SC (SM; TX:1550nm, RX:1590nm; 30-120km, WDM) with IP-Less Remote Management. |
| EM316WEFRMT/EZX |
|
2 Port Module, 1 port 10/100Base RJ45 Autosensing to 100BaseFX Single Fiber SC (SM; TX:1590nm, RX:1550nm; 30-120km, WDM) with IP-Less Remote Management. |
| EM316F/M |
|
100Base-TX (RJ45) to 100Base-FX MM (1310nm;DSC) 0-2km |
| EM316F/MX |
|
100Base-TX (RJ45) to 100Base-FX MM (1310nm;DSC) 2-8km |
| EM316F/S |
|
100Base-TX to 100Base-FX (SM, 1310nm, 0-20km, DSC). |
| EM316F/S1 |
|
100Base-TX (RJ45) to 100Base-FX SM (1310nm;DSC) 0-35km |
| EM316F/S2 |
|
100Base-TX (RJ45) to 100Base-FX SM (1310nm;DSC) 25-45km |
| EM316F/S3 |
|
100Base-TX (RJ45) to 100Base-FX SM (1550nm;DSC) 50-100km. |
| EM316F/S4 |
|
100Base-TX (RJ45) to 100Base-FX SM; (1550nm;35-110km;DSC) |
| EM316F/S5 |
|
100Base-TX to 100Base-FX, 32.8db/1550nm |
| EM316FSF/S |
|
100Base-TX (RJ45) to 100Base-FX, SM (1310nm, 0-15km, DSC). |
| EM316FSF/S2 |
|
100Base-TX (RJ45) to 100Base-FX (SC-APC) Single Fiber; SM; 1310nm; 0-35km. |
| EM316FSF/S3 |
|
100Base-TX (RJ45) to 100Base FX (SC-APC) Single Fiber; SM; 1550nm; 0-60km. |
| EM316FSF/S4 |
|
100Base-TX (RJ45) to 100Base-FX Single Fiber (SM, 1550nm, 35-100km, SC-APC). |
| EM316FSF/S5 |
|
100Base TX to 100Base FX Single Fiber (SM, 1550nm, 50-110km, RJ45/SC-APC). |
| EM316WFC/S2 |
|
2 wavelength WDM, 100BaseTX (RJ45)to Single Strand Fiber. (SM; TX:1550nm, RX:1310nm, 0-25km, SC) Must be purchased with EM316WFT/S2. |
| EM316WFT/S2 |
|
2 Wavelength WDM; 100Base TX (RJ45) to Single Strand Fiber (SM, TX:1310nm, RX: 1550nm,0-25km;SC) Must be purchased with EM316WFC/S2 |
| EM316WFC/S3 |
|
2 wavelength WDM, 100BaseTX (RJ45)to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 20-45km, SC) Must be purchased with EM316WFT/S3. |
| EM316WFT/S3 |
|
2 wavelength WDM, 100Base TX (RJ45) to Single Strand Fiber (SM, TX:1310nm, RX:1550nm, 20-45km; SC) Must be purchased with EM316WFC/S3. |
| EM316WFC/EZX |
|
2 Wavelength WDM, 100Base RJ45 to Single Strand Fiber (SM; TX:1550nm, RX:1590nm; 30-120km; SC). |
| EM316WFT/EZX |
|
2 Wavelength WDM, 100Base RJ45 to Single Strand Fiber (SM; TX:1590nm, RX:1550nm; 30-120km; SC). |
| EM316FRM/M |
|
100Base-TX (RJ45) to 100Base-FX MM (1310nm;DSC) 0-2km; WITH REMOTE MANAGEMENT; can be managed remotely from central office |
| EM316FRM/MX |
|
100Base-TX (RJ45) to 100Base-FX MM (1310nm;DSC) 2-8km; WITH REMOTE MANAGEMENT; can be managed remotely from central office |
| EM316FRM/S |
|
100Base-TX (RJ45) to 100Base-FX SM (1310nm, DSC) 0-20km; with IP-Less Remote Management. |
| EM316FRM/S1 |
|
100Base-TX (RJ45) to 100Base-FX SM (1310nm;DSC) 0-35km; WITH REMOTE MANAGEMENT; can be managed remotely from central office |
| EM316FRM/S2 |
|
100Base-TX (RJ45) to 100Base-FX SM (1310nm;DSC) 25-45km; WITH REMOTE MANAGEMENT; can be managed remotely from central office |
| EM316FRM/S3 |
|
100Base-TX (RJ45) to 100Base-FX SM (1550nm;DSC) 35-90km; WITH REMOTE MANAGEMENT; can be managed remotely from central office |
| EM316FRM/S4 |
|
100Base-TX (RJ45) to 100Base-FX SM (1550nm; 35-100km;DSC); WITH REMOTE MANAGEMENT; can be managed remotely from central office |
| EM316FRM/S5 |
|
100Base-TX (RJ45) to 100Base-FX SM (1550nm, 45-130km, DSC) with IP-Less Remote Management. |
| EM316FRMSF/S |
|
Auto-Negotiate 100Base-TX (RJ45) to 100Base-FX (SM, Single Fiber, 1310nm, SC-APC); 0-20km with IP-Less Remote Management. |
| EM316FRMSF/S2 |
|
100Base-TX (RJ45) to 100Base-FX (SC-APC) Single Fiber; SM; 1310nm; 0-35km; WITH REMOTE MANAGEMENT; can be managed remotely from central office. |
| EM316FRMSF/S3 |
|
100Base TX (RJ45) to 100Base FX (SC-APC) Single Fiber; SM; 1550nm; 25-70km; WITH REMOTE MANAGEMENT; can be managed remotely from central office. |
| EM316FRMSF/S4 |
|
100Base-TX (RJ45) to 100Base-FX (SC-APC) Single Fiber; SM (1550nm, 35-100km) with IP-Less Remote Management. |
| EM316FRMSF/S5 |
|
100Base-TX (RJ45) to 100Base-FX (SC-APC) Single Fiber; SM (1550nm, 45-130km) with IP-Less Remote Management. |
| EM316WFRMT/EZX |
|
2 Wavelength WDM, 100 Base RJ45 to Single Strand Fiber (SM; TX:1590nm, RX:1550nm; 30-120km), SC. |
| EM316WFRMC/EZX |
|
2 Wavelength WDM, 100 Base RJ45 to Single Strand Fiber (SM; TX:1550nm, RX:1590nm; 30-120km), SC. |
| EM316WFRMC/S2 |
|
2 Wavelength WDM, 100BaseTX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 0-25km, SC)with Remote Management. Must be purchase with EM316WFRMT/S2. Can be managed remotely from central office. |
| EM316WFRMT/S2 |
|
2 Wavelength WDM, 100BaseTX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 0-25km, SC) with Remote Management. MUST BE PURCHASED WITH EM316WFRMC/S2. Can be managed remotely from central office |
| EM316WFRMC/S3 |
|
2 Wavelength WDM, 100BaseTX (RJ45)to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 20-45km, SC) with Remote management. MUST BE PURCHASED WITH EM316WFRMT/S3. Can be managed remotely from central office. |
| EM316WFRMT/S3 |
|
2 Wavelength WDM, 100BaseTX (RJ45) to Single Strand Fiber (SM, TX:1550nm, RX:1310nm, 20-45km, SC) with Remote Management. MUST BE PURCHASED WITH EM316WFRMC/S3. Can be managed remotely from central office. |
| EM316EFRMOS/M |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to MM, Dual Fiber (DSC, 1310nm) with IP-Less Remote Management, 0-2km (PACKET BASED). |
| EM316EFRMOS/S |
|
Auto-negotiate 10/100Base-TX (RJ-45) Ethernet Copper to SM Dual Fiber (DSC; 1310nm) with IP-Less Remote Management; 0-20km (PACKET BASED). |
| EM316EFRMOS/S1 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Dual Fiber (DSC, 1310nm) with IP-Less Remote Management, 0-35km (PACKET BASED). |
| EM316EFRMOS/S2 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Dual Fiber (DSC, 1310nm) with IP-Less Remote Management, 25-45km (PACKET BASED). |
| EM316EFRMOS/S3 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Dual Fiber (DSC, 1550nm) with IP-Less Remote Management, 35-90km (PACKET BASED). |
| EM316EFRMOS/S4 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Dual Fiber (DSC, 1550nm) with IP-Less Remote Management, 40-110km (PACKET BASED). |
| EM316EFRMOS/S5 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Dual Fiber (DSC, 1550nm) with IP-Less Remote Management, 45-130km (PACKET BASED). |
| EM316EFRMOSF/S2 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Single Fiber (SC-APC, 1310nm) with IP-Less Remote Management, 0-35km (PACKET BASED). |
| EM316EFRMOSF/S3 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Single Fiber (SC-APC, 1550nm) with IP-Less Remote Management, 25-70km (PACKET BASED). |
| EM316EFRMOSF/S4 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Single Fiber (SC-APC, 1550nm) with IP-Less Remote Management, 35-100km (PACKET BASED). |
| EM316EFRMOSF/S5 |
|
Auto-negotiate 10/100Base-TX (RJ45) Ethernet Copper to SM, Single Fiber (SC-APC, 1550nm) with IP-Less Remote Management, 50-110km (PACKET BASED). |
| EM316FLT/M |
|
100Bse-TX (RJ45) to 100Base-FX MM (1310nm, DSC) 0-2km, operating temperature range -45 to +60 degrees C. |
| EM316FLT/MX |
|
100Bse-TX (RJ45) to 100Base-FX MM (1310nm, DSC) 2-8km, operating temperature range -45 to +60 degrees C. |
| EM316FLT/S1 |
|
100Bse-TX (RJ45) to 100Base-FX MM (1310nm, DSC) 0-35km, operating temperature range -45 to +60 degrees C. |
| EM316FLT/S2 |
|
100Bse-TX (RJ45) to 100Base-FX MM (1310nm, DSC) 25-45km, operating temperature range -45 to +60 degrees C. |
| EM316FLT/S3 |
|
100Bse-TX (RJ45) to 100Base-FX MM (1310nm, DSC) 35-90km, operating temperature range -45 to +60 degrees C. |
| EM316FLTSF/S2 |
|
100Base-TX (RJ45) to 100Base-FX (SC-APC) Single Fiber, SM, 1310nm, 0-35km. Operating temperature range -45 to +60 degrees C. |
| EM316FLTSF/S3 |
|
100Base-TX (RJ45) to 100Base-FX (SC-APC) Single Fiber, SM, 1550nm, 25-70km. Operating temperature range -45 to +60 degrees C. |
| EM316F2/MX |
|
100Base-TX (RJ45) to FX MM (DSC) Self Healing, 1310nm, 2-8km. |
| EM316F2/M |
|
100Base-TX (RJ45) to FX MM (2LC) Self Healing 1310nm; 0-4km |
| EM316F2/S1 |
|
100Base-TX (RJ45) to FX SM (2LC) Self Healing 1310nm; 0-35km |
| EM316F2/S2 |
|
100Base-TX (RJ45) to FX SM (2LC) Self Healing 1310nm; 25-50km |
| EM316F2/S3 |
|
100Base-TX (RJ45) to FX SM (2LC) Self Healing 1310nm; 50-100km |
| EM316F2SF/S2 |
|
100Base-TX (RJ45) to FX SM (2LC) Single Fiber; Self Healing; 1310nm; 0-35km. |
| EM316F2SF/S3 |
|
100Base-TX (RJ45) to FX SM (2 SC-APC) Single Fiber; Self Healing; 1310nm; 25-70km. |
| EM316F2RM/M |
|
100Base-TX (RJ45) to FX MM (2 LC) Self Healing, 1310nm, 0-4km with IP-Less Remote Management. |
| EM316F2RM/MX |
|
100Base-TX (RJ45) to FX Extended MM (2 LC) Self Healing, 1310nm, 2-8km, with IP-Less Remote Management. |
| EM316F2RM/S1 |
|
100Base-TX (RJ45) to FX SM (2 LC) Self Healing, 1310nm, 0-35km with IP-Less Remote Management. |
| EM316F2RM/S2 |
|
100Base-TX (RJ45) to FX SM (2 LC) Self Healing, 1310nm, 25-50km with IP-Less Remote Management. |
| EM316F2RM/S3 |
|
100Base-TX (RJ45) to FX SM (2 LC) Self Healing, 1310nm, 50-100km with IP-Less Remote Management. |
| EM316F2RMSF/S2 |
|
100Base-TX (RJ45)to FX SM (2 LC) Single Fiber, Self Healing, 1310nm, 0-35km with IP-Less Remote Management. |
| EM316F2RMSF/S3 |
|
100Base-TX (RJ45) to FX SM (2 LC) Single Fiber, Self Healing, 1310nm, 25-70km with IP-Less Remote Management. |
| EM316GCL/M |
|
1000Bse-TX (RJ45) to Gigabit Ethernet SX (850nm, 0-0.5km, RJ45/DSC) with LIN (Link Integrity Notification). |
| EM316GCL/MX |
|
1000Base-TX (RJ45) to Gigabit Ethernet Extended MM (1310nm; DSC), 0-2km with LIN (Link Integrity Notification). |
| EM316GCL/S1 |
|
1000Base-TX (RJ45) to Gigabit Ethernet SM (1310nm; DSC), 0-10km with LIN (Link Integrity Notification). |
| EM316GCL/S2 |
|
1000Base-TX (RJ45) to Gigabit Ethernet SM (1550nm; DSC), 0-30km with LIN (Link Integrity Notification). |
| EM316CGL/S3 |
|
1000Base-TX (RJ45) to Gigabit Ethernet SM (1550nm; DSC), 30-60km with LIN (Link Integrity Notification). |
| EM316GCLSF/S2 |
|
1000Base-TX (802.3 AB standard; RJ45) to Gigabit Ethernet SM (SC-APC), Single Fiber, 1550nm, 0-30km with LIN (Link Integrity Notification). |
| EM316GCLSF/S3 |
|
1000Base-TX (802.3 AB standard; RJ45) to Gigabit Ethernet SM (SC-APC), Single Fiber, 1550nm, 20-45km with LIN (Link Integrity Notification). |
| EM316WGCLC/S2 |
|
2 Wavelength Single Fiber, 1000Base TX (RJ45) to 1000Base FX Gigabit (SC; TX:1550nm, RX:1310nm; 0-25km). Must be purchased with EM316WGCLT/S2. |
| EM316WGCLT/S2 |
|
2 Wavelength Single Fiber, 1000Base TX (RJ45) to 1000Base FX Gigabit (SC; TX:1310nm, RX:1550nm; 0-25km). Must be purchased with EM316WGCLC/S2. |
| EM316WGCLC/S3 |
|
2 Wavelength Single Fiber, 1000Base TX (RJ45) to 1000Base FX Gigabit (SC; TX:1550nm, RX:1310nm; 25-50km). Must be purchased with EM316WGCLT/S3. |
| EM316WGCLT/S3 |
|
2 Wavelength Single Fiber, 1000Base TX (RJ45) to 1000Base FX Gigabit (SC; TX:1310nm, RX:1550nm; 25-50km). Must be purchased with EM316WGCLC/S3. |
| EM316WGCLC/EZX |
|
2 Wavelength Single Fiber, 1000Base TX (RJ45) to 1000Base FX Gigabit (SC; TX:1550nm, RX:1590nm; 30-120km). |
| EM316WGCLT/EZX |
|
2 Wavelength Single Fiber, 1000Base TX (RJ45) to 1000Base FX Gigabit (SC; TX:1590nm, RX:1550nm; 30-120km). |
| EM316FM/S |
|
100Base-FX MM; 1310nm (DSC) to 100Base-FX SM (DSC)1310nm; 0-20km. |
| EM316FM/S1 |
|
100Base-FX MM; 1310nm (DSC) to 100Base-FX SM (DSC) 1310nm; 0-35km. |
| EM316FM/S2 |
|
100Base-FX MM;1310nm (DSC) to 100Base-FX SM (DSC) 1310nm; 25-45km |
| EM316FM/S3 |
|
100Base-FX MM; 1310nm (DSC) to 100Base-FX SM (DSC); 1550nm; 35-90km |
| EM316FM/S4 |
|
100Base-FX (MM, 1310nm, DSC)to 100Base-FX (SM, 1550nm, DSC) 50-110km. |
| EM316FMSF/S2 |
|
100Base-FX MM (1310nm;DSC) to Single Fiber 100 Base-FX SM (1310nm; SC-APC); 0-35km. |
| EM316FMSF/S3 |
|
100Base-FX MM (1310nm;DSC) to Single Fiber SM (1550nm;SC-APC) 25-70km. |
| EM316FMSF/S4 |
|
100Base-FX (MM, 1310nm, DSC) to Single Fiber (SM, 1550nm, SC-APC) 35-100km. |
| EM316G/MX |
|
1000Base-SX (850nm; DSC) to Extended Multimode Fiber (1310nm, DSC, 500m/2km). |
| EM316GSF/MX |
|
1000Base-SX (Extended MM, 850nm,DSC) to Single Fiber 1000Base-LX (SM, 1310nm, SC-APC) 0-2km. |
| EM316WO3C/S2 |
|
2 wavelength WDM, OC3 MM to SM Single Strand Fiber (TX:1550nm, RX:1310nm; DSC), 0-30km. |
| EM316WO3T/S2 |
|
2 Wavelength WDM, OC3 MM to SM Single Strand Fiber (TX:1310nm, RX:1550nm, DSC), 0-30km. |
| EM316WO3C/S3 |
|
2 Wavelength WDM, OC3 MM to SM Single Strand Fiber (TX:1550nm, RX:1310nm; DSC) 20-50km. |
| EM316WO3T/S3 |
|
2 Wavelength WDM, OC3 MM to SM Single Strand Fiber (TX:1310nm, RX:1550nm; DSC), 20-50km. |
| EM316O3T/EZX |
|
2 Wavelength WDM, OC3 MM DSC to SM Single Strand Fiber SC (TX:1590nm, RX:1550nm; SC), 30-120km. |
| EM316WO3C/EZX |
|
2 Wavelength WDM, OC3 MM DSC to SM Single Strand Fiber SC (TX:1550nm, RX:1590nm; SC), 30-120km. |
| EM316O3C/M |
|
Sonet OC3 Coax (BNC) to OC MM (DSC) 1310nm;0-2km |
| EM316O3C/S |
|
Sonet OC3 Coax (BNC) to OC SM (DSC), 1310nm, 0-20km. |
| EM316O3C/S1 |
|
Sonet OC3 Coax (BNC) to OC SM S1 (DSC) 1310nm; 0-35km |
| EM316O3C/S2 |
|
Sonet OC3 Coax (BNC) to OC SM S2 (DSC) 1310nm; 25-45km |
| EM316O3C/S3 |
|
Sonet OC3 Coax (BNC) to OC SM S3 (DSC) 1550nm; 35-90km |
| EM316O3CSF/S2 |
|
SONET OC3 Coax (BNC) to Single Fiber SM S2 (SC-APC) 1310nm; 0-35km. |
| EM316O3CSF/S3 |
|
SONET OC3 Coax (BNC) to Single Fiber SM S3 (SC-APC) 1550nm; 25-70km. |
| EM316DS3/M |
|
DS3 (44.736Mbps) Coax (BNC) to MM Fiber converter (1310nm;DSC) 0-2km |
| EM316DS3/MX |
|
DS3 (44.736Mbps) Coax (BNC) to Extended MM Fiber converter (1310nm;DSC) 2-8km |
| EM316DS3/S |
|
DS3 (44.736Mbps) Coax (BNC) to SM Fiber converter (1310nm, DSC), 0-20km. |
| EM316DS3/S1 |
|
DS3 (44.736Mbps) Coax (BNC) to SM Fiber converter (1310nm;DSC) 0-35km |
| EM316DS3/S2 |
|
DS3 (44.736Mbps) Coax (BNC) to SM Fiber converter (1310nm;DSC) 25-45km |
| EM316DS3/S3 |
|
DS3 (44.736Mbps) Coax (BNC) to SM Fiber converter (1550nm;DSC) 35-90km |
| EM316DS3/S4 |
|
DS3 (44.736Mbps) Coax (BNC) to SM Fiber converter (1550nm, 40-110km). |
| EM316DS3/S5 |
|
DS3 (44.736Mbps) Coax (BNC) to SM Fiber converter (1550nm, DSC) 45-130km. |
| EM316DS3SF/S |
|
DS3 Coax (BNC) to Single Fiber SM (1310nm, SC-APC), 0-15km. |
| EM316DS3SF/S2 |
|
DS3 Coax (DSC) to Single Fiber SM (1310nm;SC-APC) 0-35km. |
| EM316DS3SF/S3 |
|
DS3 Coax(BNC) to Single Fiber SM (1550nm;SC-APC) 25-70km. |
| EM316DS3SF/S4 |
|
DS3 Coax (BNC) to Single Fiber SM (1550nm, SC-APC) 35-100km. |
| EM316WDS3C/S2 |
|
2 Wavelength WDM, DS3 (44.736Mbps) Coax (BNC) to Single Strand Fiber (SM; TX:1550nm, RX: 1310nm; 0-25km, SC). |
| EM316WDS3T/S2 |
|
2 Wavelength WDM, DS3 (44.736Mbps) Coax (BNC) to Single Strand Fiber (SM; TX:1310nm, RX: 1550nm; 0-25km, SC). |
| EM316WDS3C/S3 |
|
2 Wavelength WDM, DS3 (44.736Mbps) Coax (BNC) to Single Strand Fiber (SM; TX:1550nm, RX: 1310nm; 20-50km, SC). |
| EM316WDS3T/S3 |
|
2 Wavelength WDM, DS3 (44.736Mbps) Coax (BNC) to Single Strand Fiber (SM; TX:1310nm, RX: 1550nm; 20-50km, SC). |
| EM316E3/M |
|
E3 Coax (BNC) to MM Fiber converter (1310nm;DSC) 0-2km |
| EM316E3/MX |
|
E3 Coax (BNC) to MM Extended Fiber converter (1310nm;DSC) 2-8km |
| EM316E3/S1 |
|
E3 Coax (BNC) to SM Fiber converter (1310nm;DSC) 0-35km |
| EM316E3/S2 |
|
E3 Coax (BNC) to SM Fiber converter (1310nm;DSC) 25-45km |
| EM316E3/S3 |
|
E3 Coax (BNC) to SM Fiber converter (1550nm;DSC) 35-90km |
| EM316E3/S4 |
|
E3 Coax (BNC) to SM Fiber converter (1150nm, DSC) 40-110km. |
| EM316E3/S5 |
|
E3 Coax (BNC) to SM Fiber converter (1150nm, DSC) 45-130km. |
| EM316E3SF/S2 |
|
E3 Coax (BNC) to SM Single Fiber (1310nm; SC-APC) 0-35km. |
| EM316E3SF/S3 |
|
E3 Coax (BNC) to SM Single Fiber (1550nm;SC-APC; 25-70km. |
| EM316E1/M |
|
E1 Coax (BNC) to MM Fiber modem (820nm; 2km; ST) RJ45. |
| EM316E1/MX |
|
E1 Coax (BNC) to MM Fiber modem (820nm; 5-10km;MM;ST) |
| EM316E1/S1 |
|
E1 Coax (BNC) to SM Fiber modem (1310nm;5-30km;ST) |
| EM316E1/S2 |
|
E1 Coax (BNC) to SM Fiber modem (1310nm;25-50km;ST) |
| EM316E1/S3 |
|
E1 Coax (BNC) to SM Fiber modem (1550nm;50-100km;ST) |
| EM316E1/S4 |
|
E1 Coax (BNC) to SM Fiber modem (1550nm, 50-125km, ST). |
| EM316E1/S5 |
|
E1 Coax (BNC) to SM Fiber modem (1550nm, 50-135km, ST). |
| EM316E1RJ/M |
|
E1 Coax (RJ45) to MM Fiber modem (820nm; 0-2km; ST) |
| EM316E1RJ/S1 |
|
E1 Coax (RJ45) to SM Fiber modem (1310nm; 5-30km; ST) |
| EM316E1RJ/S2 |
|
E1 (RJ45) to SM Fiber modem (1550nm; 25-50km; ST) |
| EM316E1RJ/S3 |
|
E1 Coax (RJ45) to SM Fiber modem (1550nm; 50-100km; ST) |
| EM316E1RJ/S4 |
|
E1 (RJ45) to SM Fiber modem (1550nm, 50-125km, ST). |
| EM316E1RJ/S5 |
|
E1 (RJ45) to SM Fiber modem (1550nm, 50-135km, ST). |
| EM316E1SF/S2 |
|
E1 Coax (BNC)to SM Fiber modem, Single Fiber, (1310nm;10-40km) SC-APC |
| EM316E1SF/S3 |
|
E1 Coax (BNC) SM Fiber modem;Single Fiber (1550nm;30-90km) SC-APC |
| EM316E1SF/S4 |
|
E1 Coax (BNC) to SM Fiber modem; Single Fiber (1550nm, 40-105km) SC-APC. |
| EM316E1SF/S5 |
|
E1 Coax (BNC) to SM Fiber modem; Single Fiber (1550nm, 40-115km) SC-APC. |
| EM316T1/M |
|
T1 copper (RJ48) to MM Fiber modem (850nm;0-2km;ST) |
| EM316T1/MX |
|
T1 copper (RJ48) to MM Fiber modem (1310nm;4-10km; ST) |
| EM316T1/S1 |
|
T1 Copper (RJ48) to SM Fiber modem (1310nm;5-30km;ST) |
| EM316T1/S2 |
|
T1 Copper (RJ48) to SM Fiber modem (1310nm;25-50km;ST) |
| EM316T1/S3 |
|
T1 Copper (RJ48) to SM Fiber modem (1550nm;50-100km;ST) |
| EM316T1/S4 |
|
T1 Copper (RJ48) to SM Fiber modem (1550nm, 50-125km, ST). |
| EM316T1/S5 |
|
T1 Copper (RJ48) to SM Fiber modem (1550nm, 50-135km, ST). |
| EM316T1SF/S2 |
|
T1 Copper (RJ48)to SM Fiber modem; Single Fiber (1310nm; 10-40km) SC-APC |
| EM316T1SF/S3 |
|
T1 Copper (RJ48) to SM Fiber modem; Single Fiber (1550nm;30-90km) SC-APC |
| EM316T1SF/S4 |
|
T1 Copper (RJ48) to SM Fiber modem; Single Fiber (1550nm; 40-105km) SC-APC. |
| EM316T1SF/S5 |
|
T1 Copper (RJ48) to SM Fiber modem; Single Fiber (1550nm; 40-115km) SC-APC. |
| EM316-3SW/M |
|
3-port Switch; two port 10/100Base-TX Auto Sensing and one port 100Base-FX (MM; 1310; 0-2km; DSC) |
| EM316-3SW/MX |
|
3-port Switch;two port 10/100Base-TX (RJ45) Auto Sensing and one port 100Base-FX (MM;1310nm;2-8km;DSC) |
| EM316-3SW/S |
|
3-port Switch; (2) 10/100Base-TX (RJ45) Auto-sensing ports, and (1) 100Base-TX port (SM, 1310nm, 0-20km). |
| EM316-3SW/S1 |
|
3-port Switch; two port 10/100Base-TX (RJ45)Auto Sensing and one port 100Base-FX (SM; 1310; 0-35km; DSC) |
| EM316-3SW/S2 |
|
3-port Switch; two port 10/100Base-TX (RJ45) Auto Sensing and one 100Base-FX (SM; 1310; 25-45km; DSC) |
| EM316-3SW/S3 |
|
3-port Switch; two port 10/100Base-TX (RJ45)Auto Sensing and one 100Base-FX (SM; 1550; 35-90km; DSC) |
| EM316-3SW/S4 |
|
3-port Switch; (2) 10/100Base-TX (RJ45) Auto-sensing ports, and (1) 100Base-TX port (SM, 1550nm, 40-110km). |
| EM316-3SW/S5 |
|
3-port Switch; (2) 10/100Base-TX (RJ45) Auto-sensing ports, and (1) 100Base-TX port (SM, 1550nm, 45-130km). |
| EM316-3SWSF/S2 |
|
3-port Switch; two port 10/100Base-TX Autosensing and one port 100Base-FX (SM; 1310; 0-35km; Single Fiber;SC-APC) |
| EM316-3SWSF/S3 |
|
3-port Switch; two port 10/100Base-TX Autosensing and one port 100Base-FX (SM; 1550nm; 25-70km; Single Fiber;SC-APC) |
| EM316-3SWSF/S4 |
|
3 Port Switch; two ports 10/100Base-TX Autosensing and one port 100Base-FX (SM, 1550nm, 35-100km, Single Fiber, SC-APC). |
| EM316-4/SW |
|
4-port 10/100Base-TX (RJ45) Autosensing Switch;0-0.1km. |
| EM316-6SW/M |
|
6-port switch; Four port 10/100Base-TX (RJ45)Autosensing and two port 100Base-FX (MM; 1310nm; 0-2km) DSC |
| EM316-6SW/MX |
|
6-port switch; 4-port 10/100Base-TX (RJ45)Autosensing and 2-port 100Base-FX Extended multimode (MM; 1310nm; 2-8km; DSC) |
| EM316-6SW/S |
|
6-Port switch with (4)10/100Base-TX (RJ45) Auto-sensing ports and (2) 100Base-LX ports (SM, DSC, 1310nm, 0-20km). |
| EM316-6SW/S1 |
|
6-port switch; 4-port 10/100Base-TX (RJ45) Autosensing and 2-port 100Base-FX (SM; 1310nm; 0-35km; DSC) |
| EM316-6SW/S2 |
|
6-port switch; 4-port 10/100Base-TX (RJ45) Autosensing and 2-port 100Base-FX (SM; 1310nm; 25-45km; DSC) |
| EM316-6SW/S3 |
|
6-port switch; 4-port 10/100Base-TX (RJ45) Autosensing and 2-port 100Base-FX (SM; 1550; 35-90km; DSC) |
| EM316-6SW/S4 |
|
6-port switch; 4-port 10/100Base-TX (RJ45) Autosensing and 2-port 100Base-FX (SM, 1550nm, 40-110km, DSC). |
| EM316-6SWSF/S2 |
|
6-port switch; 4-port 10/100Base-TX Autosensing and 2-port 100Base-FX (SM; 1310; 0-35km; Single Fiber)SC-APC |
| EM316-6SWSF/S3 |
|
6-port switch; 4-port 10/100Base-TX (RJ45) Autosensing and 2-port 100Base-FX SM; 1550nm; 25-70km; Single Fiber;SC-APC |
| EM316-6SWSF/S4 |
|
6-Port Switch; Four ports 10/100Base-TX (RJ45) Autosensing and two ports 100Base-FX (SM, 1550nm, 35-100km, Single Fiber , SC-APC). |
| EM316E1MUX4/M |
|
4xE1 Copper (BNC) to Dual Fiber MM (DSC); 0-4km, 1310nm. |
| EM316E1MUX4/MX |
|
4xE1 Copper (BNC) to Dual Fiber Extended MM (DSC); 4-10km, 1310nm. |
| EM316E1MUX4/S |
|
4xE1 channels (BNC) Dual Fiber Singlemode (DSC) 1310nm, 12dB, 0-20km. |
| EM316E1MUX4/S1 |
|
4xE1 Copper (BNC)to Dual Fiber SM (DSC); 0-25km, 1310nm. |
| EM316E1MUX4SF/S2 |
|
4xE1 Copper(BNC) to Single Fiber SM (SC-APC); 0-25km, 1310nm. |
| EM316E1MUX4RJ/M |
|
4xE1 Copper (RJ48) to Dual Fiber Multimode (DSC), 1310nm, 0-4km. |
| EM316E1MUX4RJ/MX |
|
4xE1 Copper (RJ48) to Dual Fiber Extended Multimode (DSC), 1310nm, 4-10km. |
| EM316E1MUX4RJ/S |
|
4xE1 Copper (RJ48) to Dual Fiber Singlemode (DSC), 1310nm, 0-25km. |
| EM316E1X4SFJ/S2 |
|
4xE1 Copper (RJ48) to Singlemode, Single Fiber (SC-APC), 1310nm, 0-25km. |
| EM316T1MUX4/M |
|
4xT1 Mux, Copper (RJ48) to Dual Fiber MM, DSC, 1310nm, 0-4km. |
| EM316T1MUX4/MX |
|
4xT1 Copper (RJ48) to Dual Fiber Extended MM, DSC, 1310nm, 4-10km. |
| EM316T1MUX4/S |
|
4xT1 Copper (RJ48) to Dual Fiber SM, DSC, 1310nm, 020km. |
| EM316T1MUX4/S1 |
|
4xT1 Copper (RJ48) to Dual Fiber SM, DSC, 15dB @1310nm, 0-30km. |
| EM316T1XSF/S2 |
|
4xT1 Copper (RJ48) to Singlemode; Single Fiber (SC-APC) 1310nm, 0-25km. |
| EM316WT1XC/S2 |
|
4xT1 Copper (RJ45) to Single Fiber SM, Dual Wavelength, 1310/1550nm, SC, 14dB@1310, 0-25km, Sold in pairs only; must be purchased with EM316WT1MUX4T/S2. |
| EM316WT1XT/S2 |
|
4xT1 Copper (RJ45) to Single Fiber SM, Dual Wavelength: 1310/1550nm, SC, 14dB @1310, 0-25km, Sold in pairs only; must be purchased with EM316WT1MUX4C/S2. |
| CM316F-FTTX |
|
Ethernet/Fast Ethernet (RJ45) Managed Optical Termination Unit with IOE Remote Management; Includes Wide Range Power Supply. Management requires EM316NM-CL. |
| CM316FTTHRMM |
|
Ethernet/Fast Ethernet (RJ45) Managed Optical Termination unit with IOE Remote Management up to 155Mbps; 1310nm, 2km, includes Wide Range Power Supply. Management requires EM316NM-CL. |
| CM316FTTHRMIR1 |
|
Ethernet/Fast Ethernet (RJ45) Managed Optical Termination unit with IOE Remote Management up to 155Mbps; 1310nm, 20km, includes Wide Range Power Supply. Management requires EM316NM-CL. |
| CM316FTTHRMLR1 |
|
Ethernet/Fast Ethernet (RJ45) Managed Optical Termination unit with IOE Remote Management up to 155Mbps; 1310nm, 40km, includes Wide Range Power Supply. Management requires EM316NM-CL. |
| CM316FTTHRMLR2 |
|
Ethernet/Fast Ethernet (RJ45) Managed Optical Termination unit with IOE Remote Management up to 155Mbps; 1310nm, 100km, includes Wide Range Power Supply. Management requires EM316NM-CL. |
| Top |